summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--examples/Single_Shot_Conv_Ready_Controlled/Single_Shot_Conv_Ready_Controlled.ino6
1 files changed, 5 insertions, 1 deletions
diff --git a/examples/Single_Shot_Conv_Ready_Controlled/Single_Shot_Conv_Ready_Controlled.ino b/examples/Single_Shot_Conv_Ready_Controlled/Single_Shot_Conv_Ready_Controlled.ino
index 145e60c..ea76f8f 100644
--- a/examples/Single_Shot_Conv_Ready_Controlled/Single_Shot_Conv_Ready_Controlled.ino
+++ b/examples/Single_Shot_Conv_Ready_Controlled/Single_Shot_Conv_Ready_Controlled.ino
@@ -77,8 +77,12 @@ void setup() {
*
* ADS1115_CONTINUOUS -> continuous mode
* ADS1115_SINGLE -> single shot mode (default)
+ *
+ * Continuous mode does not work with conversion ready (isBusy), but it works with the
+ * conversion ready alert pin. Confusing, but that's a property of the ADS1115 and not
+ * a property of the library.
*/
- //adc.setMeasureMode(ADS1115_CONTINUOUS); //continuous mode does not work with conversion ready (isBusy)
+ // adc.setMeasureMode(ADS1115_CONTINUOUS); // continuous mode does not work with conversion ready (isBusy)
/* Choose maximum limit or maximum and minimum alert limit (window) in volts - alert pin will
* assert when measured values are beyond the maximum limit or outside the window